Performance of a MIS Type Pd-Cr/AlN/Si Hydrogen Sensor

Loading...
Thumbnail Image

Authors

Zhang, Linfeng
Al-Homoudi, Ibrahim A.
Rahman, Md H.
McCullen, Erik F.
Rimai, Lajos
Baird, Ron J.
Naik, Ratna
Newaz, Golam
Auner, Gregory W.
Ng, K.Y. Simon

Issue Date

2005

Type

Article

Language

en_US

Keywords

Hydrogen , Hydrogen sensor , Sensors

Research Projects

Organizational Units

Journal Issue

Alternative Title

Abstract

An MIS Hydrogen sensor with a Pd0.96Cr0.04/AlN/Si structure was fabricated, exhibiting the dynamic range considerably wider than that of analogous devices with pure Pd gates. A useful response could be obtained for Hydrogen concentrations as large as 50,000 ppm. Although the response amplitude was much reduced at the lower concentrations, satisfactory signal to noise down to 50 ppm could be obtained. The saturating magnitude of the electrical response is in the range of 0.1 to 0.5 V, which is the same as that for the pure Pd gated devices, inspite of the 3 orders of magnitude difference in the saturation hydrogen concentration. This result will be discussed in terms of the response mechanism of these devices.